National Instruments Deterministic Ethernet Expansion Chassis NI 9144 Manuel d'utilisateur Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 65
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
NI 9144 User Guide and Specifications 34 ni.com
Table 23 contains the default scan list.
NI 9213 Calibration Data
Calibration data is set up by the driver during initialization; the calibration
conversion is performed on the module ADC.
NI 9215
Table 23. NI 9213 Scan List Format
Index Sub Type Value
0x2001 0 ARR:U32 19
1 18
2 0
3 1
... ...
18 16
19 17
Table 24. NI 9215 Vendor Configuration Extensions
Index Sub Type R/W Description
0x2100 0 ARR:U32 Calibration = 16
1 R Ch0 Offset
2 R Ch0 Gain
... ... ...
7 R Ch3 Offset
8 R Ch3 Gain
9 R External Calibration,
Ch0 Offset
... ... ...
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 64 65

Commentaires sur ces manuels

Pas de commentaire